Detail Number | Product Name | Junction type | Developer | Wall type | Wall U-value (W/m2K) |
Floor U-value (W/m2K) |
SAP K1 ref | BRE Ψ-value (W/mK) |
BRE Temp. factor (ƒ) |
---|---|---|---|---|---|---|---|---|---|
610343 | 2.09 - Suspended ground floor slab: insulation below slab | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.17 | 0.13 | E5 | 0.119 | 0.9 |
610344 | 2.10 - Ground bearing floor slab: insulation above slab | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.17 | 0.13 | E5 | 0.038 | 0.94 |
610345 | 2.11 - Ground bearing floor slab: insulation below slab | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.17 | 0.13 | E5 | 0.057 | 0.94 |
610346 | 2.12 - Timber suspended floor | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.17 | 0.13 | E5 | 0.061 | 0.91 |
610350 | 2.16 - Ground floor (timber) / separating wall | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.0 | 0.13 | P1 | 0.104 | 0.96 |
610351 | 2.17 - Ground floor (ins. below slab) / separating wall | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.0 | 0.13 | P1 | 0.078 | 0.96 |
610352 | 2.18 - Ground floor (ins. above slab) / separating wall | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.0 | 0.13 | P1 | 0.066 | 0.97 |
610367 | 2.36 - Ground floor (inverted) | Wall-ground floor junction | Scottish Building Standards | Masonry | 0.13 | 0.13 | P6 | 0.124 | 0.83 |
610377 | 3.09 - Suspended ground floor slab: insulation below slab | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.18 | 0.13 | E5 | 0.154 | 0.88 |
610378 | 3.10 - Ground bearing floor slab: insulation above slab | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.18 | 0.13 | E5 | 0.047 | 0.92 |
610379 | 3.11 - Ground bearing floor slab: insulation below slab | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.18 | 0.13 | E5 | 0.097 | 0.92 |
610380 | 3.12 - Timber suspended floor | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.18 | 0.13 | E5 | 0.055 | 0.91 |
610384 | 3.16 - Ground floor (timber) / separating wall | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.0 | 0.13 | P1 | 0.069 | 0.94 |
610385 | 3.17 - Ground floor (ins. below slab) / separating wall | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.0 | 0.13 | P1 | 0.099 | 0.92 |
610386 | 3.18 - Ground floor (ins. above slab) / separating wall | Wall-ground floor junction | Scottish Building Standards | Timber frame | 0.0 | 0.13 | P1 | 0.092 | 0.88 |
610410 | 4.09 - Suspended ground floor slab: insulation below slab | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.17 | 0.13 | E5 | 0.137 | 0.9 |
610411 | 4.10 - Ground bearing floor slab: insulation above slab | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.17 | 0.13 | E5 | 0.055 | 0.88 |
610412 | 4.11 - Ground bearing floor slab: insulation below slab | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.17 | 0.13 | E5 | 0.073 | 0.93 |
610413 | 4.12 - Timber suspended floor | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.17 | 0.13 | E5 | 0.077 | 0.89 |
610417 | 4.16 - Ground floor (timber) / separating wall | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.0 | 0.13 | P1 | 0.063 | 0.96 |
610418 | 4.17 - Ground floor (ins. below slab) / separating wall | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.0 | 0.13 | P1 | 0.083 | 0.97 |
610419 | 4.18 - Ground floor (ins. above slab) / separating wall | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.0 | 0.13 | P1 | 0.072 | 0.95 |
610432 | 4.37 - Ground floor (inverted) | Wall-ground floor junction | Scottish Building Standards | Steel frame | 0.17 | 0.13 | P6 | 0.105 | 0.8 |