• Government Accredited Details

    Government Accredited Details

    Developed by BRE for local government



    Number of results: 12
    Detail Number Product Name Junction type Developer Wall type Wall U-value
    (W/m2K)
    Floor U-value
    (W/m2K)
    SAP K1 ref BRE Ψ-value
    (W/mK)
    BRE Temp. factor (ƒ)
    610358 2.27 - Exposed floor / separating wall Wall-exposed floor junction Scottish Building Standards Masonry 0.0 0.13 P7 0.149 0.92
    610359 2.28 - Exposed floor (inverted) Wall-exposed floor junction Scottish Building Standards Masonry 0.17 0.13 P8 0.216 0.9
    610360 2.29 - Exposed floor / external wall Wall-exposed floor junction Scottish Building Standards Masonry 0.17 0.13 E20 0.108 0.89
    610361 2.30 - Exposed floor (inverted) Wall-exposed floor junction Scottish Building Standards Masonry 0.17 0.13 E21 0.109 0.94
    610392 3.27 - Exposed floor / separating wall Wall-exposed floor junction Scottish Building Standards Timber frame 0.0 0.13 P7 0.109 0.95
    610393 3.28 - Exposed floor (inverted) Wall-exposed floor junction Scottish Building Standards Timber frame 0.18 0.13 P8 0.046 0.96
    610394 3.29 - Exposed floor / external wall Wall-exposed floor junction Scottish Building Standards Timber frame 0.18 0.13 E20 0.062 0.9
    610395 3.30 - Exposed floor (inverted) Wall-exposed floor junction Scottish Building Standards Timber frame 0.18 0.13 E21 0.032 0.98
    610425 4.27 - Exposed floor / separating wall Wall-exposed floor junction Scottish Building Standards Steel frame 0.0 0.13 P7 0.252 0.89
    610426 4.28 - Exposed floor (inverted) Wall-exposed floor junction Scottish Building Standards Steel frame 0.17 0.13 P8 0.089 0.94
    610427 4.29 - Exposed floor / external wall Wall-exposed floor junction Scottish Building Standards Steel frame 0.17 0.13 E20 0.110 0.85
    610428 4.30 - Exposed floor (inverted) Wall-exposed floor junction Scottish Building Standards Steel frame 0.17 0.13 E21 0.019 0.96