Developed by BRE for local government
Detail Number | Product Name | Junction type | Developer | Wall type | Wall U-value (W/m2K) |
Roof U-value (W/m2K) |
SAP K1 ref | BRE Ψ-value (W/mK) |
BRE Temp. factor (ƒ) |
---|---|---|---|---|---|---|---|---|---|
610334 | 2.01 - Pitched roof: ventilated roofspace - eaves | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E10 | 0.042 | 0.93 |
610335 | 2.02 - Pitched roof: ventilated roofspace - gable | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E12 | 0.087 | 0.9 |
610336 | 2.04 - Pitched roof: ventilated batten void - eaves | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E11 | -0.031 | 0.97 |
610337 | 2.05 - Pitched roof: ventilated batten void - gable | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E13 | 0.091 | 0.9 |
610338 | 2.06 - Flat roof | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E14 | 0.049 | 0.91 |
610339 | 2.07 - Flat roof with parapet | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E15 | 0.100 | 0.88 |
610353 | 2.21 - Cold roof / seprarating wall | Wall-roof junction | Scottish Building Standards | Masonry | 0.0 | 0.11 | P4 | 0.332 | 0.91 |
610354 | 2.22 - Roof / separating wall | Wall-roof junction | Scottish Building Standards | Masonry | 0.0 | 0.11 | P5 | 0.211 | 0.93 |
610362 | 2.31 - Eaves insulated at ceiling level (inverted) | Wall-roof junction | Scottish Building Standards | Masonry | 0.17 | 0.11 | E24 | 0.037 | 0.96 |
610368 | 3.01 - Pitched roof: ventilated roofspace - eaves | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E10 | 0.043 | 0.93 |
610369 | 3.02 - Pitched roof: ventilated roofspace - gable | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E12 | 0.051 | 0.97 |
610370 | 3.04 - Pitched roof: ventilated batten void - eaves | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E11 | 0.018 | 0.97 |
610371 | 3.05 - Pitched roof: ventilated batten void - gable | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E13 | 0.036 | 0.93 |
610372 | 3.06 - Flat roof | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E14 | 0.060 | 0.91 |
610373 | 3.07 - Flat roof with parapet | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E15 | 0.046 | 0.92 |
610387 | 3.21 - Cold roof / seprarating wall | Wall-roof junction | Scottish Building Standards | Timber frame | 0.0 | 0.11 | P4 | 0.090 | 0.96 |
610388 | 3.22 - Roof / separating wall | Wall-roof junction | Scottish Building Standards | Timber frame | 0.0 | 0.11 | P5 | 0.081 | 0.93 |
610396 | 3.31 - Eaves insulated at ceiling level (inverted) | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E24 | 0.049 | 0.97 |
610400 | 3.36 - Eaves insulated at ceiling level (inverted) | Wall-roof junction | Scottish Building Standards | Timber frame | 0.18 | 0.11 | E24 | 0.028 | 0.96 |
610401 | 4.01 - Pitched roof: ventilated roofspace - eaves | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E10 | 0.051 | 0.94 |
610402 | 4.02 - Pitched roof: ventilated roofspace - gable | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E12 | 0.056 | 0.93 |
610403 | 4.04 - Pitched roof: ventilated batten void - eaves | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E11 | 0.018 | 0.96 |
610404 | 4.05 - Pitched roof: ventilated batten void - gable | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E13 | 0.078 | 0.84 |
610405 | 4.06 - Flat roof | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E14 | 0.062 | 0.93 |
610406 | 4.07 - Flat roof with parapet | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E15 | 0.090 | 0.83 |
610420 | 4.21 - Cold roof / seprarating wall | Wall-roof junction | Scottish Building Standards | Steel frame | 0.0 | 0.11 | P4 | 0.196 | 0.91 |
610421 | 4.22 - Roof / separating wall | Wall-roof junction | Scottish Building Standards | Steel frame | 0.0 | 0.11 | P5 | 0.147 | 0.89 |
610429 | 4.31 - Eaves insulated at ceiling level (inverted) | Wall-roof junction | Scottish Building Standards | Steel frame | 0.17 | 0.11 | E24 | 0.031 | 0.97 |