    Detail Number Product Name Junction type Developer Wall type Wall U-value
    (W/m2K)
    Roof U-value
    (W/m2K)
    SAP K1 ref BRE Ψ-value
    (W/mK)
    BRE Temp. factor (ƒ)
    610334 2.01 - Pitched roof: ventilated roofspace - eaves Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E10 0.042 0.93
    610335 2.02 - Pitched roof: ventilated roofspace - gable Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E12 0.087 0.9
    610336 2.04 - Pitched roof: ventilated batten void - eaves Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E11 -0.031 0.97
    610337 2.05 - Pitched roof: ventilated batten void - gable Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E13 0.091 0.9
    610338 2.06 - Flat roof Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E14 0.049 0.91
    610339 2.07 - Flat roof with parapet Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E15 0.100 0.88
    610353 2.21 - Cold roof / seprarating wall Wall-roof junction Scottish Building Standards Masonry 0.0 0.11 P4 0.332 0.91
    610354 2.22 - Roof / separating wall Wall-roof junction Scottish Building Standards Masonry 0.0 0.11 P5 0.211 0.93
    610362 2.31 - Eaves insulated at ceiling level (inverted) Wall-roof junction Scottish Building Standards Masonry 0.17 0.11 E24 0.037 0.96
    610368 3.01 - Pitched roof: ventilated roofspace - eaves Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E10 0.043 0.93
    610369 3.02 - Pitched roof: ventilated roofspace - gable Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E12 0.051 0.97
    610370 3.04 - Pitched roof: ventilated batten void - eaves Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E11 0.018 0.97
    610371 3.05 - Pitched roof: ventilated batten void - gable Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E13 0.036 0.93
    610372 3.06 - Flat roof Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E14 0.060 0.91
    610373 3.07 - Flat roof with parapet Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E15 0.046 0.92
    610387 3.21 - Cold roof / seprarating wall Wall-roof junction Scottish Building Standards Timber frame 0.0 0.11 P4 0.090 0.96
    610388 3.22 - Roof / separating wall Wall-roof junction Scottish Building Standards Timber frame 0.0 0.11 P5 0.081 0.93
    610396 3.31 - Eaves insulated at ceiling level (inverted) Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E24 0.049 0.97
    610400 3.36 - Eaves insulated at ceiling level (inverted) Wall-roof junction Scottish Building Standards Timber frame 0.18 0.11 E24 0.028 0.96
    610401 4.01 - Pitched roof: ventilated roofspace - eaves Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E10 0.051 0.94
    610402 4.02 - Pitched roof: ventilated roofspace - gable Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E12 0.056 0.93
    610403 4.04 - Pitched roof: ventilated batten void - eaves Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E11 0.018 0.96
    610404 4.05 - Pitched roof: ventilated batten void - gable Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E13 0.078 0.84
    610405 4.06 - Flat roof Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E14 0.062 0.93
    610406 4.07 - Flat roof with parapet Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E15 0.090 0.83
    610420 4.21 - Cold roof / seprarating wall Wall-roof junction Scottish Building Standards Steel frame 0.0 0.11 P4 0.196 0.91
    610421 4.22 - Roof / separating wall Wall-roof junction Scottish Building Standards Steel frame 0.0 0.11 P5 0.147 0.89
    610429 4.31 - Eaves insulated at ceiling level (inverted) Wall-roof junction Scottish Building Standards Steel frame 0.17 0.11 E24 0.031 0.97