    Detail Number Product Name Junction type Developer Wall type Wall U-value
    (W/m2K)
    Roof U-value
    (W/m2K)
    SAP K1 ref BRE Ψ-value
    (W/mK)
    BRE Temp. factor (ƒ)
    610014 1.09 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E10 0.049 0.95
    610015 1.10 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E10 0.049 0.95
    610016 1.11.1 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E10 0.028 0.96
    610018 1.12.1 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E10 0.028 0.96
    610020 1.13.1 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E11 0.021 0.97
    610022 1.14 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E11 0.009 0.97
    610023 1.15 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E12 0.272 0.83
    610024 1.16 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E13 0.067 0.93
    610025 1.17 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E13 0.067 0.93
    610026 1.18 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E13 0.096 0.92
    610027 1.19 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E14 0.040 0.96
    610028 1.20 (0.21 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.21 0.16 E15 0.152 0.87
    610051 1.09 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.030 0.95
    610052 1.10 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.030 0.95
    610053 1.11.1 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.024 0.96
    610055 1.12.1 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.024 0.96
    610057 1.13.1 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E11 0.020 0.97
    610059 1.14 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E11 0.011 0.96
    610060 1.15 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E12 0.152 0.92
    610061 1.16 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E13 0.041 0.95
    610062 1.17 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E13 0.041 0.95
    610063 1.18 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E13 0.058 0.95
    610064 1.19 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E14 0.039 0.97
    610065 1.20 (0.15 - cavity and internal insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E15 0.059 0.96
    610088 1.09 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.053 0.95
    610089 1.10 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.053 0.95
    610090 1.11.1 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.037 0.96
    610092 1.12.1 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E10 0.037 0.96
    610094 1.13.1 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E11 0.036 0.97
    610096 1.14 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E11 0.034 0.97
    610097 1.15 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E12 0.210 0.84
    610098 1.16 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E13 0.063 0.94
    610099 1.17 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E13 0.063 0.94
    610100 1.18 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E13 0.071 0.93
    610101 1.19 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E14 0.038 0.97
    610102 1.20 (0.15 - cavity fill insulation) Wall-roof junction DECLG Ireland Cavity wall 0.15 0.14 E15 0.206 0.88
    610123 2.08 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E10 0.067 0.95
    610124 2.09 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E10 0.067 0.95
    610125 2.10.1 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E10 0.050 0.96
    610126 2.11.1 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E10 0.050 0.96
    610127 2.12.1 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E11 0.016 0.97
    610129 2.13 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E11 0.013 0.97
    610130 2.14 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E14 0.347 0.8
    610131 2.15 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E12 0.091 0.93
    610132 2.16 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E12 0.091 0.93
    610133 2.17 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E13 0.131 0.91
    610134 2.18 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E14 0.046 0.96
    610135 2.19 (0.21 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.21 0.16 E15 0.349 0.83
    610152 2.08 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E10 0.074 0.95
    610153 2.09 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E10 0.074 0.95
    610154 2.10.1 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E10 0.055 0.96
    610155 2.11.1 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E10 0.055 0.96
    610156 2.12.1 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E11 0.031 0.97
    610158 2.13 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E11 0.027 0.97
    610159 2.14 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E14 0.335 0.81
    610160 2.15 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E12 0.087 0.94
    610161 2.16 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E12 0.087 0.94
    610162 2.17 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E13 0.106 0.93
    610163 2.18 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E14 0.045 0.97
    610164 2.19 (0.15 - external insulation) Wall-roof junction DECLG Ireland External insulation 0.15 0.14 E15 0.327 0.85
    610180 4.09 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E10 0.082 0.9
    610181 4.10 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E10 0.082 0.9
    610182 4.11.1 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E10 0.054 0.9
    610183 4.12.1 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E10 0.054 0.9
    610185 4.13.1 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E11 0.075 0.92
    610187 4.14 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E11 0.064 0.98
    610188 4.15 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E14 0.081 0.88
    610189 4.16 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E12 0.060 0.88
    610190 4.17 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E12 0.060 0.88
    610191 4.18 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E13 0.062 0.87
    610192 4.19 (0.21 - timber frame) Wall-roof junction DECLG Ireland Timber frame 0.21 0.16 E15 0.041 0.96
    610208 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E10 0.044 0.93
    610209 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E10 0.044 0.93
    610210 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E10 0.039 0.92
    610211 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E10 0.039 0.92
    610213 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E11 0.040 0.97
    610215 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E11 0.031 0.97
    610216 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E14 0.051 0.91
    610217 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E12 0.024 0.94
    610218 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E12 0.024 0.94
    610219 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E13 0.037 0.94
    610220 4.01 (0.15 - timber frame, with internal insulation) Wall-roof junction DECLG Ireland Timber frame 0.15 0.14 E15 0.046 0.96
    610232 5.07 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E10 0.030 0.93
    610233 5.08 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E10 0.030 0.93
    610234 5.09.1 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E10 0.032 0.93
    610235 5.10.1 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E10 0.032 0.93
    610238 5.11.1 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E11 0.011 0.93
    610240 5.12 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E11 0.007 0.9
    610241 5.13 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E13 0.111 0.82
    610242 5.14 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E13 0.049 0.83
    610243 5.15 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E13 0.049 0.83
    610244 5.16 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E13 0.055 0.81
    610245 5.17 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E14 0.054 0.92
    610246 5.18 (0.21 - steel frame) Wall-roof junction DECLG Ireland Steel frame 0.21 0.16 E13 0.093 0.83
    610260 5.07 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E10 0.026 0.95
    610261 5.08 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E10 0.026 0.95
    610262 5.09.1 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E10 0.026 0.95
    610263 5.10.1 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E10 0.026 0.95
    610266 5.11.1 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E11 0.012 0.97
    610268 5.12 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E11 0.009 0.98
    610269 5.13 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E13 0.049 0.91
    610270 5.14 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E13 0.034 0.94
    610271 5.15 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E13 0.034 0.94
    610272 5.16 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E13 0.037 0.93
    610273 5.17 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E14 0.043 0.96
    610274 5.18 (0.15 - steel frame, with internal insulation) Wall-roof junction DECLG Ireland Steel frame 0.15 0.14 E13 0.054 0.95
    610290 6.08 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E10 0.021 0.94
    610291 6.09 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E10 0.021 0.94
    610292 6.10.1 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E10 0.022 0.94
    610294 6.11.1 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E11 0.003 0.97
    610296 6.12 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E11 0.011 0.96
    610297 6.13 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E14 0.038 0.92
    610298 6.14 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E13 0.026 0.94
    610299 6.15 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E13 0.026 0.94
    610300 6.16 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E13 0.036 0.93
    610301 6.17 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E14 0.053 0.96
    610302 6.18 (0.21 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.21 0.16 E13 0.046 0.95
    610316 6.08 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E10 0.021 0.95
    610317 6.09 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E10 0.021 0.95
    610318 6.10.1 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E10 0.022 0.95
    610320 6.11.1 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E11 0.002 0.98
    610322 6.12 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E11 0.015 0.97
    610323 6.13 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E14 0.034 0.93
    610324 6.14 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E13 0.022 0.95
    610325 6.15 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E13 0.022 0.95
    610326 6.16 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E13 0.031 0.94
    610327 6.17 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E14 0.039 0.97
    610328 6.18 (0.15 - hollow block, with internal insulation) Wall-roof junction DECLG Ireland Masonry 0.15 0.14 E13 0.038 0.97